| EPVX10S18AJ9W / EPSK06ARV3 | EPVX10S23AJ9W / EPSK06ARV3 | EPVX10S18AJ9W / EPSK08ARV3 | EPVX10S23AJ9W / EPSK08ARV3 | EPVX10S18AJ9W / EPSK10ARV3 | EPVX10S23AJ9W / EPSK10ARV3 | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Siseseade | EPVX10S18AJ9W | EPVX10S23AJ9W | EPVX10S18AJ9W | EPVX10S23AJ9W | EPVX10S18AJ9W | EPVX10S23AJ9W | ||||
| Küttevõimsus | Nom | kW | 5.81 (1) | 5.81 (1) | 7.62 (1) | 7.62 (1) | 8.11 (1) | 8.11 (1) | ||
| Jahutusvõimsus | Nom | kW | 6.00 (2), 6.37 (3) | 6.00 (2), 6.37 (3) | 6.89 (2), 6.37 (3) | 6.89 (2), 6.37 (3) | 7.84 (2), 6.37 (3) | 7.84 (2), 6.37 (3) | ||
| Sisendvõimsus | Küte | Nom | kW | 1.12 (1) | 1.12 (1) | 1.52 (1) | 1.52 (1) | 1.64 (1) | 1.64 (1) | |
| Jahutus | Nom | kW | 1.55 (2), 1.13 (3) | 1.55 (2), 1.13 (3) | 1.85 (2), 1.13 (3) | 1.85 (2), 1.13 (3) | 2.17 (2), 1.13 (3) | 2.17 (2), 1.13 (3) | ||
| Soe tarbevesi vahemikus 10°C kuni 50 °C | Nom | kWh | 2.35 | 2.89 | 2.35 | 2.89 | 2.35 | 2.89 | ||
| Soojendusaeg temperatuurilt 10°C temperatuurini 50 °C | t | 1 h 27 min | 1 h 58 min | 1 h 27 min | 1 h 58 min | 1 h 27 min | 1 h 58 min | |||
| COP | 5.19 (1) | 5.19 (1) | 5.01 (1) | 5.01 (1) | 4.94 (1) | 4.94 (1) | ||||
| EER | 3.87 (2), 5.63 (3) | 3.87 (2), 5.63 (3) | 3.73 (2), 5.63 (3) | 3.73 (2), 5.63 (3) | 3.62 (2), 5.63 (3) | 3.62 (2), 5.63 (3) | ||||
| Tarbevee soojendamine | Üldteave | Esitatud koormusprofiil | L | L | L | L | L | L | ||
| Keskmine kliima | Vee soojendamise energiatõhususe klass | A+ | A+ | A+ | A+ | A+ | A+ | |||
| Ruumiküte | Vee väljalase 55°C keskmises kliimas | Üldteave | SCOP | 3.91 | 3.91 | 3.97 | 3.97 | 4.02 | 4.02 | |
| Ruumikütte sesoonse tõhususe klass | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | ||||
| Vee väljalase 35°C keskmises kliimas | Üldteave | SCOP | 5.12 | 5.12 | 5.15 | 5.15 | 5.15 | 5.15 | ||
| Ruumikütte sesoonse tõhususe klass | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | ||||
| Energy Efficiency Range | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | ||||
| Märkused | (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) | (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) | (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) | (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) | (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) | (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB | (2) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB | (2) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB | (2) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB | (2) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB | (2) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB | |||||
| (3) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB | (3) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB | (3) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB | (3) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB | (3) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB | (3) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB | |||||