Tehniliste andmete tabel: EPSX07A / EPSKS-AV3

EPSX07P30AF / EPSKS04ARV3 EPSX07P50AF / EPSKS04ARV3 EPSX07P30AF / EPSKS06ARV3 EPSX07P50AF / EPSKS06ARV3 EPSX07P30AF / EPSKS07ARV3 EPSX07P50AF / EPSKS07ARV3
Siseseade EPSX07P30AF EPSX07P50AF EPSX07P30AF EPSX07P50AF EPSX07P30AF EPSX07P50AF
Küttevõimsus Nom kW 5.25 (1) 5.25 (1) 5.25 (1) 5.25 (1) 5.25 (1) 5.25 (1)
  Max kW 5.22 (2) 5.22 (2) 6.30 (2) 6.30 (2) 8.20 (2) 8.20 (2)
Jahutusvõimsus Nom kW 5.16 (3), 6.71 (4) 5.16 (3), 6.71 (4) 5.16 (3), 6.71 (4) 5.16 (3), 6.71 (4) 5.16 (3), 6.71 (4) 5.16 (3), 6.71 (4)
Sisendvõimsus Küte Nom kW 1.02 (1) 1.02 (1) 1.02 (1) 1.02 (1) 1.02 (1) 1.02 (1)
  Jahutus Nom kW 1.71 (3), 1.62 (4) 1.71 (3), 1.62 (4) 1.71 (3), 1.62 (4) 1.71 (3), 1.62 (4) 1.71 (3), 1.62 (4) 1.71 (3), 1.62 (4)
  Soe tarbevesi vahemikus 10°C kuni 50 °C Nom kWh 3.33 5.21 3.33 5.21 3.33 5.21
Soojendusaeg temperatuurilt 10°C temperatuurini 50 °C t 4 h 12 min 6 h 35 min 4 h 12 min 6 h 35 min 4 h 12 min 6 h 35 min
COP 5.17 (1) 5.17 (1) 5.17 (1) 5.17 (1) 5.17 (1) 5.17 (1)
EER 3.01 (3), 4.15 (4) 3.01 (3), 4.15 (4) 3.01 (3), 4.15 (4) 3.01 (3), 4.15 (4) 3.01 (3), 4.15 (4) 3.01 (3), 4.15 (4)
Tarbevee soojendamine Üldteave Esitatud koormusprofiil   L XL L XL L XL
  Keskmine kliima Vee soojendamise energiatõhususe klass   A+ A+ A+ A+ A+ A+
Ruumiküte Vee väljalase 55°C keskmises kliimas Üldteave SCOP   3.69 3.69 3.81 3.81 3.83 3.83
      Ruumikütte sesoonse tõhususe klass   A++ A++ A+++ A+++ A+++ A+++
  Vee väljalase 35°C keskmises kliimas Üldteave SCOP   5.03 5.03 5.05 5.05 5.05 5.05
      Ruumikütte sesoonse tõhususe klass   A+++ A+++ A+++ A+++ A+++ A+++
Energiatõhususe klass Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F
Märkused (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C) (1) - Tingimus: Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5°C)
  (2) - Condition: Ta -7°C; LWC 55°C (DT = 5°C); Heating (2) - Condition: Ta -7°C; LWC 55°C (DT = 5°C); Heating (2) - Condition: Ta -7°C; LWC 55°C (DT = 5°C); Heating (2) - Condition: Ta -7°C; LWC 55°C (DT = 5°C); Heating (2) - Condition: Ta -7°C; LWC 55°C (DT = 5°C); Heating (2) - Condition: Ta -7°C; LWC 55°C (DT = 5°C); Heating
  (3) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB (3) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB (3) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB (3) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB (3) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB (3) - Jahutus: EW 12℃; LW 7℃; ümbritseva keskkonna tingimused: 35°C DB
  (4) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB (4) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB (4) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB (4) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB (4) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB (4) - Jahutus: EW 23℃; LW 18℃; ümbritseva keskkonna tingimused: 35°C DB