Tehniliste andmete tabel: EHSXB-D3 / ERGA04-08EVA

EHSXB04P30DA3 / ERGA04EAV3A EHSXB04P50DA3 / ERGA04EAV3A EHSXB08P30DA3 / ERGA06EAV3A EHSXB08P50DA3 / ERGA06EAV3A EHSXB08P30DA3 / ERGA08EAV3A EHSXB08P50DA3 / ERGA08EAV3A
Siseseade EHSXB04P30DA3 EHSXB04P50DA3 EHSXB08P30DA3 EHSXB08P50DA3 EHSXB08P30DA3 EHSXB08P50DA3
Küttevõimsus Nom kW 4.30, 4.60 4.30, 4.60 6.00, 5.90 6.00, 5.90 7.50, 7.80 7.50, 7.80
Jahutusvõimsus Nom kW 4.86, 4.52 4.86, 4.52 5.96, 5.09 5.96, 5.09 6.25, 5.44 6.25, 5.44
Sisendvõimsus Küte Nom kW 0.840, 1.26 0.840, 1.26 1.24, 1.69 1.24, 1.69 1.63, 2.23 1.63, 2.23
  Jahutus Nom kW 0.810, 1.36 0.810, 1.36 1.06, 1.55 1.06, 1.55 1.16, 1.73 1.16, 1.73
COP 5.10, 3.65 5.10, 3.65 4.85, 3.50 4.85, 3.50 4.60, 3.50 4.60, 3.50
EER 5.98, 3.32 5.98, 3.32 5.61, 3.28 5.61, 3.28 5.40, 3.14 5.40, 3.14
Tarbevee soojendamine Üldteave Esitatud koormusprofiil   L XL L XL L XL
  Keskmine kliima Vee soojendamise energiatõhususe klass   A+ A A+ A A+ A
Ruumiküte Vee väljalase 55°C keskmises kliimas Üldteave SCOP   3.29 3.29 3.27 3.27 3.30 3.30
      Ruumikütte sesoonse tõhususe klass   A++ A++ A++ A++ A++ A++
  Vee väljalase 35°C keskmises kliimas Üldteave SCOP   4.54 4.54 4.52 4.52 4.61 4.61
      Ruumikütte sesoonse tõhususe klass   A+++ A+++ A+++ A+++ A+++ A+++
Märkused (1) - Tingimus 1: jahutus Ta 35 °C - LWE 18°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 35 °C (DT = 5 °C) (1) - Tingimus 1: jahutus Ta 35 °C - LWE 18°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 35 °C (DT = 5 °C) (1) - Tingimus 1: jahutus Ta 35 °C - LWE 18°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 35 °C (DT = 5 °C) (1) - Tingimus 1: jahutus Ta 35 °C - LWE 18°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 35 °C (DT = 5 °C) (1) - Tingimus 1: jahutus Ta 35 °C - LWE 18°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 35 °C (DT = 5 °C) (1) - Tingimus 1: jahutus Ta 35 °C - LWE 18°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 35 °C (DT = 5 °C)
  (2) - Tingimus 2: jahutus Ta 35 °C - LWE 7°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 45°C (DT = 5 °C) (2) - Tingimus 2: jahutus Ta 35 °C - LWE 7°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 45°C (DT = 5 °C) (2) - Tingimus 2: jahutus Ta 35 °C - LWE 7°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 45°C (DT = 5 °C) (2) - Tingimus 2: jahutus Ta 35 °C - LWE 7°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 45°C (DT = 5 °C) (2) - Tingimus 2: jahutus Ta 35 °C - LWE 7°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 45°C (DT = 5 °C) (2) - Tingimus 2: jahutus Ta 35 °C - LWE 7°C (DT = 5°C); kütmine Ta DB/WB 7 °C / 6 °C - LWC 45°C (DT = 5 °C)